GGM C6U4PPEDT5
The outer PE sheath ensures superior UV resistance, ideal for outdoor installations. The PVC/PE versions may also be used indoors if the outer PE sheath is removed.
Read more| Applications | IEEE802.3 : 5GBase-T, 2.5GBase-T, 1000Base-T, 100Base-Tx, 10Base-T, IEEE 802.3af/at/bt (PoE/PoE+/4PPoE) |
|---|---|
| Shielding | U/UTP |
| Category | 6 |
| Standards | EIA/TIA 568-C.2 ; ISO/IEC 11801; IEC 61156-5 ; EN50173 ; EN50288-6-1 |
| Frequency range | From 0 to 250 Mhz |
| Impedance | 100 |
| Gauge (awg) | 23 |
| Conductor type | Solid copper |
| Number of pairs | 1X4 |
| Jacket type | PVC/PE |
|---|---|
| Outer jacket colour | Black |
| Jacket RAL | RAL 9005 |
| Outer sheath diameter (mm) | 7 |
| NVP (%) | 68.2 |
| Fire behaviour | N/A |
| Insulation diameter (mm) | 1 |
| Insulation Material | Polyethylene |
| Marking | GIGAMEDIA |
| Packaging | 500 m drum |
| Shield type | U/UTP |
|---|---|
| Duplex | No |
| Conductor material | Copper |
| Conductor surface | Bare |
| Conductor OD | 0.55 mm |
| Conductor cross-section | 0.235 mm² |
| AWG size | 23 |
| Conductor construction | Class 1 = solid |
| Number of conductors | 8 |
| Number of stranding elements | 4 |
| Pairing | Pairs |
| Insulation | Other |
| Specification core insulation | Polyethylene (PE) |
| Core identification according to HD 308 S2 | No |
| Conductor identification | Colour |
| Shield | None |
| Stranding | Other |
| Longitudinal water blocking cable | No |
| Radial water blocking cable | No |
| Suitable for underground installation | No |
| Approved type of underground installation | Underground installation tube |
| Specification material outer sheath | Polyethylene (PE) |
| Jacket colour | Black |
| Armouring/reinforcement | None |
| Cable geometry | Round |
| Flame retardant according to IEC 60332-1-2 | No |
| Flame retardant according to IEC 60332-3-22 (Cat A) | No |
| Flame retardant according to IEC 60332-3-23 (Cat B) | No |
| Flame retardant according to IEC 60332-3-24 (Cat C) | No |
| Flame retardant according to IEC 60332-3-25 (Cat D) | No |
| Low smoke according to EN IEC 61034-2 | No |
| Reaction-to-fire according to EN 13501-6 | Class : Fca |
| Reaction-to-fire according to EN 13501-6 | Smoke production : None |
| Reaction-to-fire according to EN 13501-6 | Flaming droplets/particles : None |
| Reaction-to-fire according to EN 13501-6 | Acidity : None |
| Oil resistant | No |
| Cable OD | 5.8 mm |
| Installation temperature | 00 - 50 |
| Operating temperature | -20 - 60 |
| NVP | 67 % |
| Certified for shipboard application | No |
| Segregation class according to EN 50174-2 | B |
| Suitable as telephone cable | No |
| Suitable as computer data cable | Yes |
| Suitable as signalling cable | No |
| Suitable for use as security alarm cable | No |
| Drain wire | No |
| With rip cord | Yes |
| Rodent protected | No |
| Compatible with Grade2TV according to XP-C 90-483 | No |
| Compatible with Grade3TV according to XP-C 90-483 | No |
GGM C6FU4PFRT5
GGM C6F4PZHC1
GGM C6F4PZHT3
GGM C6F4PZHT5
GGM C6F4PZHTM
GGM C6F2X4PZHT5
GGM C6F4PPEC1
GGM C6F4PPET3
GGM C6F4PPET5
GGM C6U4PFRBT5
GGM C6U4PFROHT3
GGM C6U4PFROHT5
GGM C6UHR4FRU1
GGM C6UHR4FRTU3
GGM C6UHR4FRT5
GGM C6UHR4FRYT5
GGM C6UHR2X4FRT5
GGM C6UHR4WU1
GGM C6UHR4WU3
GGM C6UHR4WTU3
GGM C6UHR4WT5
GGM C6UHR2X4WT5
GGM C6UHR4PU3
GGM C6UHR4PT5
GGM C6U4PDCARU3
GGM C6U4PECARU3
GGM C6U4PPET3
GGM C6U4PPEDC1
GGM C6U4PPEDT3
GGM C6U4PHFPEC1
GGM C6U4PHFPET3
GGM C6U4PHFPET5
GGM C6U4PFRWBPET3
GGM C6U4PFRPET3
GGM C6U4PPEDT5