| Applications | IEEE802.3 : 5GBase-T, 2.5GBase-T, 1000Base-T, 100Base-Tx, 10Base-T, IEEE 802.3af/at/bt (PoE/PoE+/4PPoE) |
|---|---|
| Shielding | F/UTP |
| Category | 6 |
| Standards | EN50173, ; ISO/IEC 11801, ; ANSI/TIA-568-C.2 |
| Frequency range | From 0 to 400 Mhz |
| Impedance | 100 |
| Gauge (awg) | 24 |
| Conductor type | Solid copper |
| Number of pairs | 1X4 |
| Jacket type | LSZH |
| Outer jacket colour | Blue |
| Jacket RAL | RAL 5015 |
| Outer sheath diameter (mm) | 14.4 |
| NVP (%) | 70 |
| Insulation diameter (mm) | 1.08 |
| Marking | GIGAMEDIA EN 50173 CAT6 F/UTP LSZH C6FU4PZH -TP0051A Dca-s2 d1,a1 NVP 70% 4PAIR 24 AWG |
| Packaging | 500 m drum |
| Cable type | F/UTP |
|---|---|
| Duplex | Yes |
| Conductor material | Copper |
| Conductor surface | Bare |
| Diameter conductor | 0.53 mm |
| Nominal cross section conductor | 0.216 mm² |
| AWG size | 24 |
| Conductor category | Class 1 = solid |
| Number of cores | 16 |
| Number of stranding elements | 8 |
| Stranding element | Pairs |
| Material core insulation | Other |
| Specification core insulation | Polyethylene (PE) |
| Screen over stranding element | None |
| Stranding | Other |
| Screen over stranding | Foil |
| Longitudinal water blocking cable | No |
| Radial water blocking cable | No |
| Suitable for underground installation | No |
| Approved type of underground installation | Underground installation tube |
| Colour outer sheath | Blue |
| Cable geometry | Round |
| Flame retardant according to IEC 60332-1-2 | Yes |
| Flame retardant according to IEC 60332-3-21 (Cat A F/R) | No |
| Flame retardant according to IEC 60332-3-22 (Cat A) | No |
| Flame retardant according to IEC 60332-3-23 (Cat B) | No |
| Flame retardant according to IEC 60332-3-24 (Cat C) | No |
| Flame retardant according to IEC 60332-3-25 (Cat D) | Yes |
| Reaction-to-fire according to EN 13501-6 | Class : Dca |
| Reaction-to-fire according to EN 13501-6 | Smoke production : s2 |
| Reaction-to-fire according to EN 13501-6 | Flaming droplets/particles : d1 |
| Reaction-to-fire according to EN 13501-6 | Acidity : a1 |
| Circuit integrity according to IEC 60331-23 | Yes |
| Oil resistant according to EN IEC 60811-404 | No |
| Outer diameter approximate | 7.2 mm |
| Min. permitted bending radius, moving application/free movement | 8 mm |
| Min. permitted bending radius, stationary application/permanent installation | 4 mm |
| Permitted cable outer temperature after assembling without vibration | -20 - 75 |
| NVP value | 70 % |
| Suitable as telephone cable | No |
| With rip cord | Yes |
| Characteristic impedance | 100 Ohm |
| Max. tensile strength during installation | 400 kN |
GGM C6FU4PFRT5
GGM C6F4PZHC1
GGM C6F4PZHT3
GGM C6F4PZHT5
GGM C6F4PZHTM
GGM C6F2X4PZHT5
GGM C6F4PPEC1
GGM C6F4PPET3
GGM C6F4PPET5
GGM C6U4PFRBT5
GGM C6U4PFROHT3
GGM C6U4PFROHT5
GGM C6UHR4FRU1
GGM C6UHR4FRTU3
GGM C6UHR4FRT5
GGM C6UHR4FRYT5
GGM C6UHR2X4FRT5
GGM C6UHR4WU1
GGM C6UHR4WU3
GGM C6UHR4WTU3
GGM C6UHR4WT5
GGM C6UHR2X4WT5
GGM C6UHR4PU3
GGM C6UHR4PT5
GGM C6U4PDCARU3
GGM C6U4PECARU3
GGM C6U4PPET3
GGM C6U4PPEDC1
GGM C6U4PPEDT3
GGM C6U4PPEDT5
GGM C6U4PHFPEC1
GGM C6U4PHFPET3
GGM C6U4PHFPET5
GGM C6U4PFRPET3
GGM C6U4PFRWBPET3
GGM C6U4PFRWBPEU200
GGM C6U4PDCAROU3
GGM C6FU4PZHT5
GGM C6FU4PZHT3
GGM C6FU4PZHC1
GGM C6FU2X4PZHT5