GGM C6AFF2X4DBET5
Tested at 550 MHz, and certified by an independent laboratory (3P), GIGAMEDIA CAT6A cables are designed to exceed the Class Ea specification, and ensure Ethernet applications up to 10 Gigabits/s, as well as PoE (remote supply according to IEEE 802.3af/at). Its general and pair screening optimises Next performance, and ensures optimal bandwidth.
Read more
| Applications | IEEE802.3 : 10GBase-T, 5GBase-T, 2.5GBase-T, 1000Base-T, 100Base-Tx, 10Base-T, IEEE 802.3af/at/bt (PoE/PoE+/4PPoE) |
|---|---|
| Shielding | F/FTP |
| Category | 6A |
| Standards | ANSI/TIA-568.2-D ; EN 50173 ; ISO/IEC 11801 |
| Frequency range | From 0 to 550 Mhz |
| Impedance | 100 |
| Gauge (awg) | 23 |
| Conductor type | Solid copper |
| Number of pairs | 2X4 |
| Jacket type | LSZH |
|---|---|
| Outer jacket colour | Blue |
| Jacket RAL | RAL 5013 |
| Outer sheath diameter (mm) | 7 |
| NVP (%) | 82 |
| Fire behaviour | EN 13501-6 : Dca s2 d1 a1 ; EN 50575 ; EN 50399 ; EN 60332-1-2 |
| Insulation diameter (mm) | 1.32 |
| Insulation Material | Polyethylene |
| Marking | GIGAMEDIA EN 50173 CAT6A F/FTP LSZH -C6AFF2X4ZH -TP022A ? Dca NVP 82% 2X4PAIR 23 AWG [lot n°] XXXXXX m |
| Packaging | 500 m drum |
| Shield type | F/FTP |
|---|---|
| Duplex | Yes |
| Conductor material | Copper |
| Conductor surface | Bare |
| Conductor OD | 0.574 mm |
| Conductor cross-section | 0.259 mm² |
| AWG size | 23 |
| Conductor construction | Class 1 = solid |
| Number of conductors | 16 |
| Number of stranding elements | 8 |
| Pairing | Pairs |
| Insulation | Other |
| Specification core insulation | Polyethylene (PE) |
| Core identification according to HD 308 S2 | No |
| Conductor identification | Colour |
| Shield | Foil |
| Stranding | Other |
| Longitudinal water blocking cable | No |
| Radial water blocking cable | No |
| Suitable for underground installation | No |
| Approved type of underground installation | Underground installation tube |
| Jacket colour | Blue |
| Armouring/reinforcement | None |
| Cable geometry | Round |
| Flame retardant according to IEC 60332-1-2 | Yes |
| Flame retardant according to IEC 60332-3-22 (Cat A) | No |
| Flame retardant according to IEC 60332-3-23 (Cat B) | No |
| Flame retardant according to IEC 60332-3-24 (Cat C) | No |
| Flame retardant according to IEC 60332-3-25 (Cat D) | Yes |
| Low smoke according to EN IEC 61034-2 | Yes |
| Reaction-to-fire according to EN 13501-6 | Class : Dca |
| Reaction-to-fire according to EN 13501-6 | Smoke production : s2 |
| Reaction-to-fire according to EN 13501-6 | Flaming droplets/particles : d1 |
| Reaction-to-fire according to EN 13501-6 | Acidity : a1 |
| Oil resistant | No |
| Cable OD | 7 mm |
| Installation temperature | 00 - 50 |
| Operating temperature | -20 - 70 |
| NVP | 82 % |
| UV resistant | No |
| Certified for shipboard application | No |
| Segregation class according to EN 50174-2 | C |
| Suitable as telephone cable | No |
| Suitable as computer data cable | Yes |
| Suitable as signalling cable | No |
| Suitable for use as security alarm cable | No |
| Drain wire | Yes |
| With rip cord | No |
| Rodent protected | No |
| Compatible with Grade2TV according to XP-C 90-483 | No |
| Compatible with Grade3TV according to XP-C 90-483 | No |
GGM C6AFF4PFRBT5
GGM C6AFF4PFRT5
GGM C6AFF4PSFRU1
GGM C6AFF4PSFRU200
GGM C6AFF4PSFRU3
GGM C6AFF4PSFRT5
GGM C6AFF4PZHT5
GGM C6AFF2X4ZHT5
GGM C6AFF4PDBET5
GGM C6AFF4PSHFU1
GGM C6AFF4PSHFU200
GGM C6AFF4PSHFU3
GGM C6AFF4PSHFT5
GGM C6AFF4PFRWBPET3
GGM C6AUF4PFRT5
GGM C6AU4PFRT5
GGM C6AUF4PZHT3
GGM C6AUF4PZHT5
GGM C6AUF2X4ZHT5
GGM C6AF4PZHT3
GGM C6AF4PZHT5
GGM C6AF4PZHTM
GGM C6AF2X4ZHT5
GGM C6AUF4PHFU3
GGM C6AUF4PHFT5
GGM C6AUF2X4HFT5
GGM C6AUF4PPET3
GGM C6AU4PFRTU3
GGM C6AFF2X4DBET5