GGM F24B4CFIRST
Indoor/outdoor loose tube cable (250 µm fibres), HFFR outer jacket. Its Halogen Free Flame Retardant and UV resistant outer jacket is perfectly adapted for the most demanding environments and allows to maintain circuit integrity up to 3 hours in case of fire. Thanks to a CST reinforcement, it is also highly resistant to crushing and can be directly buried into the ground.
Read more| Produit | Loose tube LSZH Fire resistant |
|---|---|
| Operating environment | Indoor / Outdoor |
| Fiber amount | 24 |
| Cable type | Loose tube |
| Strength member | : Corrugated steel tape + glass yarns |
| Watertightness | Waterblocking glass yarns |
| Diameter (mm) | 9 |
| Bending radius - minimum static (mm) | 90 |
| Bending radius - minimum dynamic (mm) | 180 |
| Crush resistance (N) | 2000 |
| Outer sheath | LSFRZH |
| Fire behaviour | IEC 60332-3/IEC60331-25/PH120 EN 50200 |
| Outer jacket colour | Orange |
| Operating temperature | -40°C to +70°C |
| Cable weight (kg/km) | 142 |
| Packaging | 2000m |
| Marking | [Length] [GIGAMEDIA] [GGM F24B4CFIRST] [24FO 50/125 OM4 CLT LSZH FE180/PH120] [Week/Year] [Supplier Lot No (op.no)] |
| Bandwidth @850 nm | ≥ 4700 |
| Bandwidth @1300 nm | ≥ 500 |
| Bandwidth at 1310/1550 nm | None |
| Number of fibres | 24 |
|---|---|
| Type of tube | Central tube |
| Number of fibres per tube | 24 |
| Fibre type | Multi mode 50/125 |
| Category | OM4 |
| With strain relief | No |
| With rodent protection | Yes |
| Armouring/reinforcement | Lap-screen |
| Material armouring | Steel |
| Material outer sheath | Other |
| Specification material outer sheath | Other |
| Colour outer sheath | Orange |
| Longitudinal water blocking cable | Yes |
| Radial water blocking cable | Yes |
| Cable metal free | No |
| Cable geometry | Round |
| Flame retardant according to IEC 60332-1-2 | Yes |
| Flame retardant according to IEC 60332-3-21 (Cat A F/R) | Yes |
| Flame retardant according to IEC 60332-3-24 (Cat C) | Yes |
| Low smoke according to EN IEC 61034-2 | Yes |
| Halogen free according to EN IEC 60754-1 | Yes |
| Halogen free according to EN IEC 60754-2 | Yes |
| Reaction-to-fire according to EN 13501-6 | Class : None |
| Reaction-to-fire according to EN 13501-6 | Smoke production : None |
| Reaction-to-fire according to EN 13501-6 | Flaming droplets/particles : None |
| Reaction-to-fire according to EN 13501-6 | Acidity : None |
| Oil resistant according to EN IEC 60811-404 | No |
| Resistant to chemicals | No |
| Outer diameter approximate | 9 mm |
| Min. permitted bending radius, stationary application/permanent installation | 90 mm |
| Max. tensile strength during installation | 1200 kN |
| Suitable for underground installation | Yes |
| Blow in | Yes |
| Weight | 142 kg/km |
GGM F6B3CFIRST
GGM F12B3CFIRST
GGM F24B3CFIRST
GGM F48B3CFIRST
GGM F6B4CFIRST
GGM F12B4CFIRST
GGM F48B4CFIRST
GGM F6B9CFIRST
GGM F12B9CFIRST
GGM F24B9CFIRST
GGM F48B9CFIRST
GGM F24B4CFIRST