GGM F24R12G6A2ST

24FO FTTH riser G657A2 cable with 12 fibers per gel-free micromodule LSZH DCA

Perfect for use in riser columns in collective residential environments. The FRP reinforcement in the LSZH sheath provide additional rigidity. Access to the fibres is easy and the function of opening a cable run reduces operational costs linked to connections in floor boxes (passing cables). The micromodular technology offers the possibility of opening the tubes / modules and accessing the fibres without tools. Modular with 6 fibres per tube.

Read more
Perfect for use in riser columns in collective residential environments. The FRP reinforcement in the LSZH sheath provide additional rigidity. Access to the fibres is easy and the function of opening a cable run reduces operational costs linked to connections in floor boxes (passing cables). The micromodular technology offers the possibility of opening the tubes / modules and accessing the fibres without tools. Modular with 6 fibres per tube.

AVCP System AVCP3
Conformity IEC 60793-2-50 type B6
Euroclass short Dca
Installation temperature From -5°C to +60°C
Operating temperature From -10°C to +60°C
Weight 70 (12 in) to 130 kg (144 in)
Jacket LSFROH
Storage temperature From -40°C to +70°C
Fiber type Singlemode G657A2
Colour Ivory
Marking [Length] [GIGAMEDIA 24FO G657A2 12F/T EASY MODULE LSOH Dca s2 d0 a1 FOC MOD12] [Week/Year]
Modularity 12 fibers per module
Tensile strength (n) 400

ETIM features

Number of fibres 24
Type of tube Loose tube
Number of fibres per tube 12
Fibre type Single mode 9/125
Category Other
With strain relief No
With rodent protection No
Armouring/reinforcement Other
Material armouring Other
Material outer sheath Other
Specification material outer sheath Other
Colour outer sheath White
Longitudinal water blocking cable No
Radial water blocking cable No
Cable metal free Yes
Cable geometry Round
Flame retardant according to IEC 60332-1-2 Yes
Flame retardant according to IEC 60332-3-21 (Cat A F/R) No
Low smoke according to EN IEC 61034-2 Yes
Reaction-to-fire according to EN 13501-6 Class : Dca
Reaction-to-fire according to EN 13501-6 Smoke production : s2
Reaction-to-fire according to EN 13501-6 Flaming droplets/particles : d0
Reaction-to-fire according to EN 13501-6 Acidity : a1
Oil resistant according to EN IEC 60811-404 No
Resistant to chemicals No
Outer diameter approximate 8.7 mm
Min. permitted bending radius, stationary application/permanent installation 130.5 mm
Max. tensile strength during installation 4 kN
Suitable for underground installation No
Blow in Yes